Downloads read more ...
Brochure DYWIDAG Bonded Post-Tensioning Systems using Strands,
Filesize:2.4 MB
Filesize:2.4 MB
Approval ETA-06 0022 DYWIDAG Bonded Strand PT-System,
Filesize:2.0 MB
Filesize:2.0 MB
Technical Document Strands - Calculation of Elongation,
Filesize:39 kB
Filesize:39 kB
Bonded Strand Post-Tensioning System
Coupler M/ME Floating Anchorage Block
| type 0,6" | ultimate load Ø 12.9mm (265kN per strand) | ultimate load Ø 15.7mm (279kN per strand) | A | B | C | D | A D | B D | E |
| kN | kN | mm | mm | mm | mm | mm | mm | mm | |
| 6801 | 265 | 279 | 98 | 55 | 200 | 20 | - | - | - |
| 6802 | 530 | 558 | 90 | 105 | 120 | 40 | 60 | 70 | 200 |
| 6804 | 1,060 | 1,116 | 130 | 160 | 120 | 55 | 70 | 130 | 650 |
| 6806 | 1,590 | 1,674 | 130 | 160 | 120 | 65 | 70 | 130 | 650 |
| 6808 | 2,120 | 2,232 | 130 | 210 | 120 | 75 | 70 | 170 | 1,050 |
| 6810 | 2,650 | 2,790 | 168 | 210 | 120 | 80 | 100 | 170 | 1,150 |
| 6812 | 3,180 | 3,348 | 168 | 210 | 120 | 80 | 100 | 170 | 1,150 |
| details of the Anchorage zone | block-out dimensions | ||||||
| Ø15.7mm, ultimate load 265/279kN | |||||||
| type 0,6" | X | Y | Z | type 0,6" | L2 | LR | |
| mm | mm | mm | mm | mm | |||
| 6801 | 100 | 180 | 60 | 6801 | - | - | |
| 6802 | 130 | 155 | 50 | 6802 | 550 | 550 | |
| 6804 | 180 | 195 | 70 | 6804 | 700 | 600 | |
| 6806 | 180 | 195 | 70 | 6806 | 700 | 600 | |
| 6808 | 230 | 195 | 70 | 6808 | 1,350 | 600 | |
| 6810 | 230 | 235 | 90 | 6810 | 1,500 | 800 | |
| 6812 | 230 | 235 | 90 | 6812 | 1,500 | 800 | |