DYWIDAG Prestressing Systems using Bars
Equipment for stressing and grouting

Tensioning jack 110 Mp/60 Mp Tensioning jack HOZ 200 Mp
Dimensions (for Block-Out design)
|
|

- Pump Type 77-193 A

- Pump Type R 6.4
Hydraulic pumps
| Hydraulic pumps | Tensioning jacks | ||
| 60 Mp | 110 Mp | 200Mp | |
| 77-193-A | |||
| R 3.0 V | |||
| R 6.4 | |||
| Pump type | max. operating pressure | oil flow rate | usable oil capacity | weight with oli 1) | dimensions LxWxH |
| [bar] | [l/min] | [l] | [kg] | [mm] | |
| 77-193-A | 600 | 3.0 | 10 | 63 | 420x380x480 |
| R 3.0 V | 600 | 3.0 | 13 | 98 | 600x390x750 |
| R 6.4 | 600 | 6.4 | 70 | 310 | 1400x700x1100 |
1) hydraulic pumps are supplied without oil

- Mixer MP 2000-5
Grouting equipment (mixing and pumping)
| Grouting equipment | max. injection pressure | capacity | weight | dimensions LxWxH |
| [bar] | [l/h] | [kg] | [mm] | |
| MP 2000-5 | 15 | 420 | 300 | 2000x950x1600 |