DYWIDAG Prestressing Systems using Bars
Geometrical characteristics of accessories
| THREADBAR ® | Plain bar | ||||||||||
| Bar designation | 18 WR | 26 WR | 32 WR | 36 WR | 40 WR | 47 WR | 32 WS | 36 WS | |||
| Domed anchor nut | 2099 | length | [mm] | 55 | 75 | 90 | 100 | 115 | 135 | 46 | 60 |
| width across flat | [mm] | 36 | 50 | 60 | 65 | 70 | 80 | 55 | 65 | ||
| Hex nut 4 | 2002 | length | [mm] | 60 | 80 | 90 | 110 | 120 | 140 | 55 | 80 |
| width across flat | [mm] | 41 | 46 | 55 | 60 | 70 | 80 | 55 | 60 | ||
| Coupler (standard) | 3003 | length | [mm] | 100 | 170 | 200 | 210 | 245 | 270 | 110 | 160 |
| outside diameter | [mm] | 36 | 50 | 60 | 68 | 70 | 83 | 60 | 68 | ||
| Square Solid Plate | 2011 | width | [mm] | 110 | 150 | 180 | 200 | 220 | 260 | 180 | 200 |
| length | [mm] | 110 | 150 | 180 | 200 | 220 | 260 | 180 | 200 | ||
| thickness | [mm] | 25 | 35 | 40 | 45 | 45 | 50 | 40 | 45 | ||
| Rectangular Solid Plate (Unbonded and Bonded) | 2012 | width | [mm] | 100 | 130 | 140 | 150 | 160 | 200 | 140 | 150 |
| length | [mm] | 130 | 150 | 180 | 220 | 250 | 280 | 180 | 220 | ||
| thickness | [mm] | 30 | 35 | 40 | 50 | 60 | 60 | 40 | 50 | ||
| Rectangular Solid Plate (Bonded) | 2076 | width | [mm] | 80 | 120 | 140 | 160 | 180 | 210 | 140 | 160 |
| length | [mm] | 90 | 130 | 165 | 180 | 195 | 235 | 165 | 180 | ||
| thickness | [mm] | 25 | 30 | 35 | 40 | 45 | 55 | 35 | 40 | ||
| QR-Plate | 2074 | width | [mm] | - | 120 | 140 | 160 | 180 | - | - | 160 |
| length | [mm] | - | 130 | 165 | 180 | 195 | - | - | 180 | ||
| thickness | [mm] | - | 30 | 35 | 40 | 45 | - | - | 40 | ||
| Corrugated Duct | 4061 | internal diameter | [mm] | 25 | 38 | 44 | 51 | 55 | 65 | 44 | 51 |
| outside diameter | [mm] | 30 | 43 | 49 | 56 | 60 | 70 | 49 | 56 | ||
| Minimum Bar Protrusion at stressing anchorage | [mm] | 60 | 75 | 90 | 100 | 115 | 135 | 46 | 60 | ||
4 Hex nuts 2002 are not included at ETA-05/0123
Overview of tensioning jacks for prestressing Tendons
| THREADBAR ® | Plain bar | |||||||
| Bar Designation | 18 WR | 26 WR | 32 WR | 36 WR | 40 WR | 47 WR | 32 WS | 36 WS |
| 60 Mp | ||||||||
| 110 MP | ||||||||
| 200 Mp | ||||||||
1 stressing force limited to 625 kN max.