GEWI ® Threadbar System
Assembly Instructions
The GEWI ® connecting reinforcements
- Coupler bar type M
- Hook bar type W
- Loop bar type S
- Anchoring bar type E
- Connecting bar type P
are delivered with a pre-mounted coupler and are to be fixed to the formwork prior to concreting.
The GEWI ® coupler can be assembled quickly and easily:
- Marking of the screw-in length at the fifth rib to ensure the turning in of four ribs of the rod.
- Screwing on a lock nut and a coupler on steel rod 1 and a lock nut on steel rod 2.
- Joining the steel rods together and screwing up the coupler. Checking with the marking if booth steel rods are turned in sufficiently into the coupler.
- Hand-screwing the lock nuts against the coupler.
- Locking the nut with the required torque using special torque wrenches.
Installation procedure for the GEWI ® connecting reinforcement
- Nail the plug onto the formwork at the desired position.
- Screw the GEWI ® Coupler Bar Type M on manually
- After the formwork has been demoulded, screw off the plug.
- Screw in GEWI ® Coupler Bar Type A and lock it with the required torque.