DYWIDAG Ground Anchors

Ground Anchors

Bar Anchors - Technical Data

Prestressing Steel
Bar DiameterSteel GradeUltimate StrengthYield Strength
mmN/mm2kN (fpu)kN (Ty)
15900/1100195159
20900/1100345283
26.5950/1050579523
32950/1050844764
36950/10501069967
40950/105013201194
47950/105018221648
GEWI ®-Steel
Bar DiameterSteel GradeUltimate StrengthYield Strength
mmN/mm2kN (fpu)kN (Ty)
16500/600121100
20500/600188157
25500/600295245
28500/600370308
32500/600482402
40500/600756630
50500/6001176980
63.5555/70022171758
GEWI ® Plus -Steel
Bar DiameterSteel GradeUltimate StrengthYield Strength
mmN/mm2kN (fpu)kN (Ty)
18670/800204170
22670/800304255
25670/800393329
28670/800493413
30670/800565474
35670/800770645
43670/8001162973
57.5670/80020771740
63.5670/80025342122

Temporary Bar Anchor
 

(Lifespan: up to 2 years)

 

Permanent Bar Anchor
with Double Corrosion Protection

(Lifespan: up to 120 years)

DYWIDAG Temporary Bar Anchor
1- Anchor Nut
2- Bearing Plate
3- Sleeved Duct
(through concrete slab)
4- Debond Sleeve
(smooth sheathing)
5- Heatshrink Seal
6- Threadbar
A-Free Length
B-Bond Length
DYWIDG Permanent Bar Anchor with Double Corrosion Protection
1- Anchor Nut
2- Steel Cap
3- Bearing Plate
4- Anti-Corrosion Compound
5- Steel Stub Tube
6-Threadbar
7-Debond Sleeve
(over corrugated sheathing)
8-Heatshrink Seal
9-Borehole grout
10-Factory Grout
11-Corrugated Plastic Sheathing
12-Grout Cap
A-Free Length
B-Bond Length
DYWIDAG Ground Anchors Spacer
  1. Lantern Spacer - plain bar (soil or rock)
  2. Lantern Spacer (cased boreholes, soil)
  3. Wrap around spacer (stable boreholes, rock)

Corrosion Protection for Permanent Bar Anchors

Permanent Anchors (lifespans in excess of 2 years) require sufficient corrosion protection to ensure durability throughout the working life of each anchor. Double Corrosion Protection, featuring factory pregrouted encapsulation of the bar within a corrugated plastic sheath, ensures comprehensive protection to all parts of the anchor. Protection at the anchor head is provided by a fully enclosed assembly. Borehole Grout is not recognised as a corrosion protection barrier by current anchor standards (BS8081 or EN1537) .

Corrosion Protection for Permanent Bar Anchors

Bond Length

  1. Threadbar
  2. Encapsulated Grout (factory applied)
  3. Corrugated Sheathing

Free Length

  1. Encapsulated Grout (factory applied)
  2. Corrugated Sheathing
  3. Debond Sleeve
Corrosion Protection for Permanent Bar Anchors

Coupler

  1. Heatshrink seal (top and bottom)
  2. Coupler
  3. Collar (top and bottom)