Ground Anchors
Bar Anchors
Technical Data
|
|
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Temporary Bar Anchor
(Lifespan: up to 2 years)

Permanent Bar Anchor with Double Corrosion Protection
(Lifespan: up to 120 years)

| Lantern Spacer - plain bar (soil or rock) | Lantern Spacer (cased boreholes, soil) | Wrap around spacer (stable boreholes, rock) |
![]() | ||
Corrosion Protection for Permanent Bar Anchors
Permanent Anchors (lifespans in excess of 2 years) require sufficient corrosion protection to ensure durability throughout the working life of each anchor. Double Corrosion Protection, featuring factory pregrouted encapsulation of the bar within a corrugated plastic sheath, ensures comprehensive protection to all parts of the anchor. Protection at the anchor head is provided by a fully enclosed assembly. Borehole Grout is not recognised as a corrosion protection barrier by current anchor standards (BS8081 or EN1537) .