Ground Anchors

Bar Anchors

Technical Data

Prestressing Steel
Bar DiameterSteel GradeUltimate StrengthYield Strength
mmN/mm2kN (fpu)kN (Ty)
15900/1100195159
20900/1100345283
26.5950/1050579523
32950/1050844764
36950/10501069967
40950/105013201194
47950/105018221648
GEWI ®-Steel
Bar DiameterSteel GradeUltimate StrengthYield Strength
mmN/mm2kN (fpu)kN (Ty)
16500/600121100
20500/600188157
25500/600295245
28500/600370308
32500/600482402
40500/600756630
50500/6001176980
63.5555/70022171758
GEWI Plus ®-Steel
Bar DiameterSteel GradeUltimate StrengthYield Strength
mmN/mm2kN (fpu)kN (Ty)
18670/800204170
22670/800304255
25670/800393329
28670/800493413
30670/800565474
35670/800770645
43670/8001162973
57.5670/80020771740
63.5670/80025342122

Temporary Bar Anchor

(Lifespan: up to 2 years)

 

Permanent Bar Anchor with Double Corrosion Protection

(Lifespan: up to 120 years)

 


Lantern Spacer - plain bar (soil or rock)Lantern Spacer (cased boreholes, soil) Wrap around spacer (stable boreholes, rock)

Corrosion Protection for Permanent Bar Anchors

Permanent Anchors (lifespans in excess of 2 years) require sufficient corrosion protection to ensure durability throughout the working life of each anchor. Double Corrosion Protection, featuring factory pregrouted encapsulation of the bar within a corrugated plastic sheath, ensures comprehensive protection to all parts of the anchor. Protection at the anchor head is provided by a fully enclosed assembly. Borehole Grout is not recognised as a corrosion protection barrier by current anchor standards (BS8081 or EN1537) .